Recent content by G33RT

  1. G33RT

    How to access older IP camera's on newer browsers ?

    I have an old laptop with a old IE version and with that I can access the camera's. Still I like to access them on Windows 10 and with a modern browser. Yes indeed strange, in what browser can you access your camera settings screen ? I'll gona try that browser to see what it does, thanks for...
  2. G33RT

    How to access older IP camera's on newer browsers ?

    The video stream is not my problem, I can't access any camera settings, I need to setup static IP and video preferences also NTP of my choice.
  3. G33RT

    How to access older IP camera's on newer browsers ?

    Hi, Is it possible to access older IP camera's on newer (year 2022) browsers ? Back in 2015 I used to use IE and when access the camera IP you where questioned to install a ActiveX because without it won't work. Then it would ask you to download a file named NewActive.exe from xmsecu.com...
  4. G33RT

    is there a mirror site of XM (xiongmaitech) IPC firmwares ?

    Does someone knows if there is any mirror site of the XM (xiongmaitech) IPC firmwares ? Many of the firmwares I need have expired and can't be downloaded anymore like: 00002510.1版IPC50H10L_S38_V4.02.R11 (xm030.cn) 00006531.1版IPC18E_53H13_S38_V4.0.R12 (xm030.cn) Thanks in advance !
  5. G33RT

    Anran AR-24NB-IP partial funtion after FW update

    Okay, there is also a KH25L12845EMI-10G flash memory chip on the PCB.
  6. G33RT

    Anran AR-24NB-IP partial funtion after FW update

    I another strange thing. The bootloader report a (Macronix) MX25L128 flash chip but there is no such chip on the PCB. The flash chip on the PCB is actually a (Atmel) AT88SC0104CA Could this be Pro-programmed in the bootloader or some config? U-Boot 2010.06-svn (Oct 14 2015 - 15:02:08) DRAM...
  7. G33RT

    Anran AR-24NB-IP partial funtion after FW update

    Seems that I still have the wrong firmware. The manufacturer does not have the firmware anymore (don't want to do some effort) to help me. So close but no cigar. I update this threat if I succeed.
  8. G33RT

    Anran AR-24NB-IP partial funtion after FW update

    Since I never done this via serial console can you give me an example of the commands I have to use? I can transfer the file or files via bootloader "loady 0x8?000000" command and sent binaries via Y-modem protocol. I also seen somewhere that whole firmware is flashed via this way but I can't...
  9. G33RT

    Anran AR-24NB-IP partial funtion after FW update

    I found some more information on the camera: SoC Chip: Hi3516C V100 Camera module: 53H20L Image sensor: OV9712 # cd utils # ls upgraded # upgraded LibCrypto : g_cryptotype = 0 ********************************************************************** | SYSTEM INFO |...
  10. G33RT

    Anran AR-24NB-IP partial funtion after FW update

    I have managed to get Telnet access with the tool called OpenTelnet, login: root passw: xmhdipc LocalHost login: root Password: Welcome to Monitor Tech. # # ls bin etc linuxrc proc share tmp var boot home mnt root slv usr dev lib opt...
  11. G33RT

    Anran AR-24NB-IP partial funtion after FW update

    Also the command 'getinfo' gives me nothing about the hardware: hisilicon # getinfo getinfo - print hardware information hisilicon #
  12. G33RT

    Anran AR-24NB-IP partial funtion after FW update

    Unfortunately the command 'devinfo' is not recognized. hisilicon # devinfo Unknown command 'devinfo' - try 'help' What about that hardware ID ? HWID=8043420000030000
  13. G33RT

    Anran AR-24NB-IP partial funtion after FW update

    Okay, I admid I could made have flashed a wrong firmware as I'm not 100% sure it was the right one. Thought if you accedently flash the wrong firmware you would be notify by some error, apparently NOT... The firmware I got is from: www.xiongmaitech.com (thought these are refference firmwares...
  14. G33RT

    Anran AR-24NB-IP partial funtion after FW update

    @ port 9527 I connect PuTTY as Telnet and receive continious this debug message: [DEBUG]: Libfvideo: Mpp! [DEBUG]: Product_Info: 0 [DEBUG]: Product_SubInfo : LAN LIBDVR : will save NID = 000000, g_fd = 9 LIBDVR : Save environment to flash ,Please wait ...... LIBDVR : Note!! don't power off...
  15. G33RT

    Ip Cam Hi3516c boot loop after configuration change. Any help?

    Hi Agustin, It's been a long time but I'm curious did you ever recovere those camera's ?